SKU: 9013FHG54S174J55X1. Discussion in 'Pumps and Tanks Well Forum & Blog. Turn the switch back off and proceed to diagnose why the switch was not turning the well pump on and off automatically. Otherwise, the structure won’t work as it … 4. Review any system discrepancies or perceived problems in operation. CUT-OUT Turn the smaller differential nut down for higher cut-out pressure (clockwise) which increases the differential between cut in … I just want my pump to be protected just in case we would run out of water. If the setting for the pressure switch is 28 psi, then the tank's reading should be 26 psi. Or a broken bladder with water on top of it. Troubleshooting a Pumptrol pressure switch is relatively simple. Looking for SQUARE D Air Compressor Pressure Switch; Range: 40 to 150 psi, Port Type: (1) Port, 1/4 in FNPS (2PXN7)? If the switch doesn’t close when the pressure drops then the spring is bad and you’ll need to replace the entire switch. What does 20/40, 30/50, 40/60, 50/70, and 60/80 mean? Pumps that are 1.5 hp and below you can just use the regular non-heavy duty pressure switch. Click Here to view other pressure switch technical videos/docs. It reveals the parts of the circuit as simplified shapes, and also the power and also signal connections in between the gadgets. The pressure switch does not control how much pressure your pump makes, it only turns on and off as the pressure in your system drops or increases signaling the switch to turn ON/OFF. Check the air pressure and adjust to … Most of the major switch manufacturers have their Owner’s Manual available on their websites. Welcome to Terry Love Plumbing & Remodel DIY & Professional Forum. If you feel small holes then the contacts are bad. Doesn't sound like a workable situation either way. http://cyclestopvalves.com/prod_sensor.html, (You must log in or sign up to reply here. Part number SQD-HP – high pressure switch • Pressure range: 25-80 psi • Mount 1/4” BSPF • Factory setting: 30-50 psi. Pressure Control Switch Guides. Captive cover screw. The whole system was designed by the Meyers pump company. 5. Next, remove the old switch (Photo 2) and gauge (Photo 3). Part number SQD-HP – high pressure switch • Pressure range: 25-80 psi • Mount 1/4” BSPF • Factory setting: 30-50 psi. Imagine that there was a leak or break in your water line. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. Use a wrench that fits the two small nuts on top of the two springs. This is what LLigetfa was asking about when he posted "Does the switch have a low pressure cutoff?". View in Order History. Suitable for jet pumps, submersible pumps and reciprocating pumps. Dimensions: 3.76" W x 2.8" H x 2.78" L. SQUARE D BY SCHNEIDER ELECTRIC. Pressure switch too far from tank. A low cut off pressure switch turns the pump off in the event that the water pressure in your lines drops lower than the cut-in pressure (low number). It also shuts the pump off after the pressure in your tank has reached the preset limit. What does a Heavy Duty Pressure Switch do? Save To List . If you see electrical sparks, turn off the power right away and replace your switch. If you see the switch open and close it might have just been stuck because of some built up debris. The FSG2J21BP has a 30 psi to 50 psi pressure setting range activates an electrically driven water pump within a power circuit when the adjustable rising and falling thresholds are reached. A wiring diagram is a streamlined conventional photographic depiction of an electrical circuit. The Type FSG - PUMPTROL Water Pump Pressure Switches are used to control electrically driven water pumps, suitable for all types of pumps: jets, submersible, reciprocating, etc. The Pumptrol FSG2J21BP electromechanical pressure switch by Square D is the most trusted brand in residential, commercial and industrial pumping applications. Then disconnect the wiring (Photo 1). Wrap the pipe threads with Teflon tape and reassemble. If the contacts stay open and there’s no pressure, then the switch is bad. How to Take Care of Your Bolted Pressure Switch Bolted Pressure Switch Maintenance Requirements. It reveals the parts of the circuit as simplified shapes, and also the power and also signal connections in between the gadgets. Square D Pressure Switches; Square D Pressure Switches Square D Pressure ... Quick Connect 2-Way Release, 1/4" 4-way Flange, Low HP, 100-200 PSI, Off at 150 PSI 9013FHG54S174J55X1 Air Comp. Call today for more information. Check the pressure switch using a pressure gauge. The switch then powers up the well pump. Pressure Switches control electrically driven water pumps predicated on set pressure variances. Turn the spring clockwise to increase the cut-off and cut-in pressure. Pull the plastic cover from the pressure switch by removing the single nut on top of the cover. Pumps are used to bring up the water from the well and to pressurize the water pipes in the home. Flip the breaker to the pump switch and check it with a voltage sniffer to make sure it’s off. Shop Water Pump Pressure Switch By Square D (Schneider Electric) (9013FSG2J24) At Graybar, Your Trusted Resource For Pressure Switches And Other Square D (Schneider Electric) Products. A wiring diagram is a streamlined conventional photographic depiction of an electrical circuit. The 'short' cycling is usually caused by insufficient air pressure in the pressure tank. Not your question? For example on a 40/60 pressure switch (most popular option) a home’s water pressure sits at 60 psi. Part number – SQD-LOP – loss of prime pressure switch • Pressure range: 20-65 psi • With low pressure … This might help loosen up the spring. // ]]> When you turn the faucet off, the pump will continue to pump until the pressure gets back to 60 psi and that’s when the pressure switch will send a signal to your pump to turn off. Turn the spring clockwise to increase the cut-off and cut-in pressure. Bolted pressure switches are mainly used in the industrial realm. A power surge can cause a breaker to trip and shut off the flow of water as well. As time goes on, the spring becomes weak and the electrical contacts wear out which can make it seem that your pump isn’t working quite right. Wrap the pipe threads with Teflon tape and reassemble. SQD-LOP Pressure range: 20-65 psi; Factory setting: 20-40 psi; With low pressure cut out lever; Mount 1/4” BSPF; $128.77. Example Pump Pressure Switch Adjustment Instructions from Square-D Pressure Control. Next, remove the old switch (Photo 2) and gauge (Photo 3). SQUARE D CPD FSG2J21CP SQUARE D PRESSURE SWITCH 30-50PSI. From the start with this switch it did not want to keep the contacts closed at start up. Due to increased demand, it may take us a little longer to get your order ready. You can read online Square D Class 9012 Pressure Switch Manual or load. Part number – SQD-LOP – loss of prime pressure switch • Pressure range: 20-65 psi • With low pressure … Shut off the peower to the pump. Variety of square d pumptrol pressure switch wiring diagram. It was rated at 30/50 but after installation it was actually cutting in and out at about 25/45. Condor Pressure Switches. How to Adjust the Rating of Square-D 9013 Pressure Switch from Schneider Electric To adjust please follow the Proper Sequence: 1. Quantity: remove_circle Please enter a product quantity above 0 add_circle. gtag('config', 'AW-948175282/-9a3CNG7j3gQsoOQxAM', { 'phone_conversion_number': '800-767-8731' }); Square D Pressure Switch 9013 Adjustment We see a lot of Goulds jet pumps here in Ct, the number one problem is rust that accumulates over the port for the pressure switch tube on the pump body. Square D Pumptrol Water pressure switches are ideal for rural customers who usually rely on wells to supply their water. Looking for SQUARE D Water Pump Pressure Switch; Range: 5 to 65 psi, Port Type: (1) Port, 1/4 in FNPS (2FH02)? Close the valve from the pressure tank to the house. SQUARE D PUMPTROL 9013 TROUBLESHOOTING [PDF] guide from Schneider Electric, Schneider Electric - North America, 2641 Sumner Boulevard, Raleigh, NC 27616 USA, Tel: 800-468-5342 www.us.squared.com www.us.telemecanique.com Tel: Square D product support group, 888-SquareD; SQUARE D PUMPTROL 9013 WIRING & ADJUSTMENT [PDF] When working we got great pressure. Close the valve from the pressure tank to the house. Please refer to Data Bulletin 9013DB0701 it is a good source for maintenance and troubleshooting guidelines. All prices are inclusive of GST. Drain the pressure tank. Turn the spring to adjust the Square D well pressure switch Looking at the pressure, locate the large spring in the center. When someone opens up a faucet, it goes from 60 psi down to 40 psi. Check out the contact points and if the discs are black, pry it apart and feel the discs. PRESSURE SWITCH, DPDT, 100PSI. Square "D" Pressure Switch with Lever, Unloader and 4 Port Manifold, Factory PSI Setting 95-125, Differential PSI 30 (Smaller HP) Square "D" Pressure Switch with Lever, Unloader and 4 Port Manifold, Factory PSI Setting 110-150, Differential PSI 40 (Smaller HP) Price: $57.24. For example 40/60 psi, the tank should be set to 38 psi. We do not want the same pressure to switch the pump on and off and so in fact there are two pressure switches each set at a predetermined pressure. The pressure switch on your well is responsible for automatically sensing the need for more water in your pressure tank and supplying power to the pump. (38 PSI), We are committed to providing the highest quality water filtration and well system supplies at the lowest prices. Putting a regular pressure Switch may help, But defeats the purpose of having low pressure cutoff. We have found that a drill type torch tip cleaner is just the tool to use to clean those ports. Variety of air compressor pressure switch wiring diagram. These numbers represent the pressures that your pressure switch is tuned to in the water line. Aug 26, 2012 You'll find the pressure switch mounted on a 1/4-in. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. If the switch doesn’t close when the pressure drops then the spring is bad and you’ll need to replace the entire switch. Kill the power to the compressor completely when you are wiring a compressor pressure switch. [CDATA[ Flip the breaker to the pump switch and check it with a voltage sniffer to make sure it’s off. Price $30.99. On a Square-D Pumptrol™ 9013FSF-2 pump pressure switch, for example, Square D tells us that we It's a Meyers submersible pump. The pressure switch has a spring on the inside that’s connected to electrical contacts. Hubbell-Furnas Pressure Switches. Standard action contacts. Great prices & free shipping on orders over $50 when you sign in or sign up for an account. Description: Incoming Well Pump Pressure Switch Wiring Diagram Supply From Fuse with regard to Square D Well Pump Pressure Switch Wiring Diagram, image size 290 X 430 px, and to view image details please click the image.. When you open up a faucet the pressure drops. KP pressure controls are designed to protect refrigeration systems from excessively high discharge p.. $75.90 Ex Tax: $75.90 If you see electrical sparks, turn off the power right away and replace your switch. Application:To control electrically driven water pumps, Approvals:UL Listed File: E12158 CCN NKPZ - CSA Certified File: LR25490, Depth:2.78 Inches Diaphragm:Nitrile (Buna N), Range on Decreasing Pressure:10 to 45 PSIG, Range on Increasing Pressure:20 to 65 PSIG, Includes:Low pressure cut-off (operates at approximately 10 PSIG below cut-in and will turn off the pump), Horsepower Rating:(Single Phase) 1.5HP@115VAC - 2HP@230VAC (Polyphase) 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. 00 $21.40 $21.40 The pumps I play with for work on large chillers these days have transducers for flow and no pressure switch as they run continuously. Next turn the electricity back on. Record the pressure switch setting if available. Confirm that electrical power is available and that circuit breakers (or fuses) are operational. The following are the instructions for resetting the switch, assuming your pressure switch is a Square D Pumptrol Model FSG-2-M4, an extremely common switch (pictured below): Turn off all water faucets and water using appliances Chattering Square D pressure switch, and check valve location. //